Model NO. VS1-12/3150A-31.5KA
Arc-extinguishing Medium Vacuum
Installation Fixed
Structure Vcb
Poles Number 3
Type Circuit Breaker
Function Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification VDE, ISO9001-2000, CE, CB, CCC
Rated Current 630A 1250A
Functions Overvoltage,Overload,Overtemperature
Types Draw-out Fixed
Rated Voltage 12kv 24kv 35kv
Mechanical Life 10000 Times
Transport Package Pallet Wooden
Specification 600x900x2000
Trademark MINGZHE
Origin China
HS Code 8535299000
Production Capacity 500PCS/Week
Product Description
Product Description

1 Summarize
VS1 type indoor high voltage vacuum circuit breaker is one kind of three-phase AC 50Hz, rated voltage is 7.2-12 kv, indoor high voltage switch equipment. The circuit breaker meets the national standard of Chinese, GB1984-2003 <ac high-voltage circuit breaker>, JB 3855-1996 <3.6-40.5kv indoor high-voltage vacuum breaker>, DI403-91 < 10-35kv indoor high-voltage vacuum circuit breaker ordering technical conditions >and related IEC60694, IEC6227-100 standard requirements which with reliable interlocking function.
VS1 type indoor high voltage vacuum circuit breaker can be operated frequently, with the ability of multiple breaking and quick reclosing.
The VS1 type indoor high-voltage vacuum circuit breaker is designed with front and rear sub-assembly structure, which can be used for fixed installation cells as well as equipped with a separate hand cart with a chassis.

Detailed Photos
Product Parameters
Rated Voltage12Kv
Rated Frequency50Hz
Rated lightning impulse test voltage/fracture75/85kV(peak)
Rated at 1 min, withstand voltage/fracture
  • 42/48kV(effective values)
  • Rated operating sequence
O-t-CO-t'-CO
ModelRated Current(kA)Rated short circuit breaking current (kA)
  • Rated short close current KA(Peak)kA
  • Rated duration time of short-circuit S
  • Breaking times
  • Mechanical lifetime
VS1-12630
1250
20/2550/63
4
10010000
1250
1600
2000
2500
31.58045010000
1250
1600
2000
2500
3150
4010043010000

Note: 20 kA, 25 kA, 31.5 kA, t= 0.3S, t'=180S
40kA t=180S t'=180S
b) Mechanical characteristics of circuit breaker
ModelItemsUnitData
1Contact distancemm11±1
2Overtravel3.5±0.5
3The characteric of three phase opening and closing at different period ms≤2
4Closing contact jumping timeMs≤2
5Closing contact contact pressureN20kA25 kA31.4 kA40 kA
2000± 2002400 ±2003100± 2004750± 250
6Average Closing speedm/s0.9-1.2
7Average Opening speed 05-0.8

c) Opening and Closing action time
Closing time ≤100ms
Opening time ≤50ms
Arcing time ≤15ms
Breaking time ≤65ms
1.2.2 Technical data for trip and interlock electromagnet
ItemPower VA
Opening trip TQ368
220/110
Closing trip HQ368
Interlock trip Y14.8
Overcurrent trip 7(Y8 Y9)--

1.2.3 Technical data for motor operation mechanism
Rated Voltage VPower WStorage time SApplicable current Level kA
220/11070≤1020 25 31.5
220/110100≤1040

Certifications

Indoor Vcb Vacuum Circuit Breaker/Lbs Breaker/Load Break Switch/Vcb Vd4

Packaging & Shipping

Indoor Vcb Vacuum Circuit Breaker/Lbs Breaker/Load Break Switch/Vcb Vd4

Company Profile

Indoor Vcb Vacuum Circuit Breaker/Lbs Breaker/Load Break Switch/Vcb Vd4

Indoor Vcb Vacuum Circuit Breaker/Lbs Breaker/Load Break Switch/Vcb Vd4

Our AdvantagesAfter Sales Service
Send inquiry
Send